CVE-2026-34766
Electron: USB device selection not validated against filtered device list
描述
### Impact The `select-usb-device` event callback did not validate the chosen device ID against the filtered list that was presented to the handler. An app whose handler could be influenced to select a device ID outside the filtered set would grant access to a device that did not match the renderer's requested `filters` or was listed in `exclusionFilters`. The WebUSB security blocklist remained enforced regardless, so security-sensitive devices on the blocklist were not affected. The practical impact is limited to apps with unusual device-selection logic. ### Workarounds There are no app side workarounds, you must update to a patched version of Electron. ### Fixed Versions * `41.0.0-beta.8` * `40.7.0` * `39.8.0` * `38.8.6` ### For more information If there are any questions or comments about this advisory, send an email to [security@electronjs.org](mailto:security@electronjs.org)
如何修補 CVE-2026-34766
要修補 CVE-2026-34766,請將受影響套件升級到下列已修補版本。
- —升級至 38.8.6 或更新版本
CVE-2026-34766 正在被利用嗎?
低 — EPSS 為 0.2%,目前沒有觀察到大規模利用活動。
受影響套件(1)
- from 0, < 38.8.6
CVSS 分數
| 來源 | 版本 | 嚴重程度 | 向量 |
|---|---|---|---|
| osv | CVSS 3.1 | LOW3.3 | CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:L/I:L/A:N |